W 型锅炉二次供风系统档板开度的计算
2007-08-01 15:01:25 来源:
A-
A+
电力18讯: W 型锅炉二次供风系统档板开度的计算
陈宝明, 李立人,
(上海理工大学动力
程智海, 文4涓士蜀
学院,上海200093)
摘 要:W 型火焰锅炉在发电厂有着广泛应用。但是,目前此种锅炉二次风供风系统的调节是凭经
验进行的,为了使它的调节更迅速、更有效,运用了流体力学管路理论,对此种锅炉二次风供风系统
建立数学模型,进行计算分析,得到在任一给定工况下各档板开度的计算方法和计算公式,并进行
了实例计算,计算结果与现场运行情况基本一致。表明:这种计算方法在实际工程应用中是可行的。
今后当工况发生改变时,就可以方便地运用本计算方法,指导各档板的调节。图5表4参4
关键词:动力机械工程;W 型火焰锅炉;二次风供风系统;流量控制;挡板开度
中图分类号:TK223.21 文献标识码:A
Calculation of Baffle in the Secondary W ind System for
W Burning Boiler
CH EN Bao―ruing,L1 Li―ren,CHEN Zhi―hai,LlU Juan―juan
(College of Power Engineering,Shanghai University of Science and Technology,Shanghai 200093,China)
Abstract:W burning boiler is widely used in power plants.But nowadays the adjustment of the secondary
wind system in the kind of W burning boiler is made by experience.In order to make the adjustment of it
more rapidly and more efficiently,the pipeline theory of fluid mechanics is used.A mathematic model is
made for the secondary wind system in the kind of boiler,and calculation and analysis is done.The method
and formulation of calculation of baffle’s opening degree in any given working conditions is obtained.and
calculation is made on a specific example.These results are consistent primarily with running conditions on
the site.So the method of calculation is practicable in the practical engineering application and convenient
to use the calculation method to guide the adjustment of baffles when the working conditions is changed.
Figs5,tables 4 and refs 4.
Key words:power and mechanical engineering;W burning boiler;secondary wind system of control;flux
control;baffle’S opening degree
1 概况
W 型火焰锅炉分为上下两个炉膛,如图1所
示。下炉膛为燃烧室,前后墙向外扩展形成炉拱,拱
顶布置燃烧器。煤粉气流从燃烧器垂直向下喷人燃
收稿日期:2003―12―22
作者简介:陈宝明(1978一),男,安徽无为人,硕士研究生。
烧室,着火后火焰向下发展,在离开燃烧器喷口一定
距离处和分级送人的二次风混合后转弯向上流动,
火焰在整个燃烧室内呈W 形状。
DG一1025/18.2一Ⅱ型W 火焰锅炉有一个环形
二次风箱。所有24支燃烧器和二次风挡板均布置在
风箱内,如图2所示。在风箱四角各有一个压力计以
测量二次风的压力,正常运行中其表压力P 通常处
在500Pa~-1000Pa之间。炉膛负压P。一般维持在
维普资讯 https://www.cqvip.com
动 力 工 程 第24卷
一50Pa(表压)。进入炉膛的二次风风量由不同的挡
板组(A、B、C、D、E、F)控制。每只燃烧器有由6个挡
板来进行配风,总共有12×2×6―144个挡板,如图
3(a)所示。
图1 W 型火焰锅炉示意图
Fig 1 W burning boiler
图2 二次风主风道
Fig 2 M ain airway of the secondary wind
对w 型火焰锅炉来说,调整二次风供风系统各
挡板的进风量,就可以改善燃烧的配风结构,提高锅
炉运行效率。因此,当锅炉运行时,及时调节各挡板
的开度是重要的。在这方面,山西阳泉第二发电厂根
据经验做了一些试验,绘出了流速与压力、流速与挡
板开度的一些曲线,作为操作指导n]。本文将对W
型火焰锅炉二次风供风系统运用流体力学管路计算
理论[z,31进行计算,得出在任一工况(如流量、压力)
下各挡板的开度,使锅炉在高效率下运行,提高它的
经济性。并以山西阳泉第二发电厂的DG一1025/18.
2一Ⅱ型w 火焰锅炉为算例。
2 原理
为了提高锅炉的效率,就要使煤粉和空气充分
接触,为此应尽量使通过各组中每一块挡板的流量
相等,即通过24块A挡板的流量一样,通过24块B
挡板的流量相等,以此类推。由于风道中存在阻力,
及A、B、C、D、E、F各挡板的几何尺寸不同,如图3
(b)所示。为了保证流量相等,各挡板的开度就必须
不一样。考虑到二次风主风道四角处压力相等,且对
称位置的挡板开度是一样的,这样就可以把对144
块挡板开度的计算简化为对其中任一角处的6×6
块挡板开度的计算。但在实际操作中C挡板通常是
关闭的,因<
陈宝明, 李立人,
(上海理工大学动力
程智海, 文4涓士蜀
学院,上海200093)
摘 要:W 型火焰锅炉在发电厂有着广泛应用。但是,目前此种锅炉二次风供风系统的调节是凭经
验进行的,为了使它的调节更迅速、更有效,运用了流体力学管路理论,对此种锅炉二次风供风系统
建立数学模型,进行计算分析,得到在任一给定工况下各档板开度的计算方法和计算公式,并进行
了实例计算,计算结果与现场运行情况基本一致。表明:这种计算方法在实际工程应用中是可行的。
今后当工况发生改变时,就可以方便地运用本计算方法,指导各档板的调节。图5表4参4
关键词:动力机械工程;W 型火焰锅炉;二次风供风系统;流量控制;挡板开度
中图分类号:TK223.21 文献标识码:A
Calculation of Baffle in the Secondary W ind System for
W Burning Boiler
CH EN Bao―ruing,L1 Li―ren,CHEN Zhi―hai,LlU Juan―juan
(College of Power Engineering,Shanghai University of Science and Technology,Shanghai 200093,China)
Abstract:W burning boiler is widely used in power plants.But nowadays the adjustment of the secondary
wind system in the kind of W burning boiler is made by experience.In order to make the adjustment of it
more rapidly and more efficiently,the pipeline theory of fluid mechanics is used.A mathematic model is
made for the secondary wind system in the kind of boiler,and calculation and analysis is done.The method
and formulation of calculation of baffle’s opening degree in any given working conditions is obtained.and
calculation is made on a specific example.These results are consistent primarily with running conditions on
the site.So the method of calculation is practicable in the practical engineering application and convenient
to use the calculation method to guide the adjustment of baffles when the working conditions is changed.
Figs5,tables 4 and refs 4.
Key words:power and mechanical engineering;W burning boiler;secondary wind system of control;flux
control;baffle’S opening degree
1 概况
W 型火焰锅炉分为上下两个炉膛,如图1所
示。下炉膛为燃烧室,前后墙向外扩展形成炉拱,拱
顶布置燃烧器。煤粉气流从燃烧器垂直向下喷人燃
收稿日期:2003―12―22
作者简介:陈宝明(1978一),男,安徽无为人,硕士研究生。
烧室,着火后火焰向下发展,在离开燃烧器喷口一定
距离处和分级送人的二次风混合后转弯向上流动,
火焰在整个燃烧室内呈W 形状。
DG一1025/18.2一Ⅱ型W 火焰锅炉有一个环形
二次风箱。所有24支燃烧器和二次风挡板均布置在
风箱内,如图2所示。在风箱四角各有一个压力计以
测量二次风的压力,正常运行中其表压力P 通常处
在500Pa~-1000Pa之间。炉膛负压P。一般维持在
维普资讯 https://www.cqvip.com
动 力 工 程 第24卷
一50Pa(表压)。进入炉膛的二次风风量由不同的挡
板组(A、B、C、D、E、F)控制。每只燃烧器有由6个挡
板来进行配风,总共有12×2×6―144个挡板,如图
3(a)所示。
图1 W 型火焰锅炉示意图
Fig 1 W burning boiler
图2 二次风主风道
Fig 2 M ain airway of the secondary wind
对w 型火焰锅炉来说,调整二次风供风系统各
挡板的进风量,就可以改善燃烧的配风结构,提高锅
炉运行效率。因此,当锅炉运行时,及时调节各挡板
的开度是重要的。在这方面,山西阳泉第二发电厂根
据经验做了一些试验,绘出了流速与压力、流速与挡
板开度的一些曲线,作为操作指导n]。本文将对W
型火焰锅炉二次风供风系统运用流体力学管路计算
理论[z,31进行计算,得出在任一工况(如流量、压力)
下各挡板的开度,使锅炉在高效率下运行,提高它的
经济性。并以山西阳泉第二发电厂的DG一1025/18.
2一Ⅱ型w 火焰锅炉为算例。
2 原理
为了提高锅炉的效率,就要使煤粉和空气充分
接触,为此应尽量使通过各组中每一块挡板的流量
相等,即通过24块A挡板的流量一样,通过24块B
挡板的流量相等,以此类推。由于风道中存在阻力,
及A、B、C、D、E、F各挡板的几何尺寸不同,如图3
(b)所示。为了保证流量相等,各挡板的开度就必须
不一样。考虑到二次风主风道四角处压力相等,且对
称位置的挡板开度是一样的,这样就可以把对144
块挡板开度的计算简化为对其中任一角处的6×6
块挡板开度的计算。但在实际操作中C挡板通常是
关闭的,因<