[摘要] 随着反渗透脱盐工艺的广泛应用,反渗透膜的污染因其与处理工艺、预处理效果以及各地水源水质的不同,会产生各种各样的污染。反渗透膜污染到一定程度,就必须进行清洗。而反渗透膜在遭受重度污染的情况下,在线清洗已经不能够满足膜元件性能恢复的需要,离线清洗就成为解决这一问题的唯一办法。本文主要介绍了反渗透膜重度污染的原因、特征以及离线清洗操作方法、清洗配方的选择和清洗实例,以供同行参阅。
[关键词] 反渗透;重度污染;离线清洗
The serious contamination and cleaning off-line of RO membrane
SONG Jing-po
(Begin chemical,zhengzhou 450012,China)
Abstract: With the application of RO unit,contamination appears in different forms due to different preconditions and different water sources. The problems of the cleaning of membrane is following with the contamination. But the cleaning on-line become not enough when the contamination is serious, the only choice is the cleaning off-line. This paper introduces the reasons and characteristics of serious contaminated RO membrane,the selection of prescription of the cleaning membrane,emphases on operation and concrete examples in order to consult with professionals.
Key words:reverse osmosis(RO);serious contamination;cleaning off-line
反渗透系统因其先进的技术及经济特性,已形成国内各行业庞大的用户群,据不完全统计,目前国内反渗透水处理用户已超过数千家。
反渗透膜元件作为深层的过滤手段,其表面不可避免的会残留有胶体、微生物、杂质颗粒及难溶盐类在其表面的析出,因此,在多种领域使用的反渗透装置,一旦投入使用,最终都需要清洗,只是清洗周期的长短不同而已。然而,在线清洗作为一种反渗透系统清洗保养、冲击性杀菌以及定期保护的手段,在面临反渗透膜元件重度污染时就显得无能为力,这个时候就需要对反渗透膜元件进行离线清洗。
1 反渗透膜元件重度污染的原因、特征
虽然反渗透系统的设计中都会有一定程度的富裕量,以保证在紧急时刻不至于因为反渗透系统的产水量或脱盐率下降、反渗透系统压差升高而使得供水不足而对安全生产造成威胁,但实际上也正是由于这些富裕量的存在才使得有时候隐藏的故障不能够及时的表现出来,这样最终可能就演变为反渗透膜元件的重度污染。
1.1 反渗透膜元件重度污染的概念
指反渗透系统进水中所含的悬浮物、胶体、有机物、微生物及其它颗粒对RO膜产生的表面附着、沉积污染或者水中的化学离子成分在膜表面因浓差极化等因素导致的离子积大于溶度积后的化学垢类生成等现象。重度污染则指污染后的单段压差大于系统投运初期单段压差值的2kgf/cm2以上、反渗透系统产水量较额定产水量下降30%以上、进水压力超过正常压力3kgf/cm2以上或者单支反渗透膜元件重量超过正常数值3公斤以上的情况。
重度污染往往是重度物理污染和重度化学污染的叠加,某些情况下,二者同时伴生。
1.2 反渗透膜元件重度污染的原因及特征
由于各地水源水质不同,所采用的与处理方式也不尽相同,所以RO膜元件的原因也不尽相同,常见的污染原因及特征有以下几种:
1.2.1 水处理工艺系统设计及制造缺陷
(1)对于反渗透预处理过滤器来讲,源水未井水的情况下,设备滤速大于8.5米/小时,而地表水设计中设备滤速大于8米/小时,导致反渗透进水SDI超标;(2)源水中含有胶体、悬浮物等杂质,而在设计中没有去除措施;(3)源水中COD>3而没有去除措施;(4)反渗透膜元件设计通量超标的反渗透装置二段结垢及压差升高快,产水量衰减及脱盐率下降快.
以上(1)、(2)、(3)设计缺陷可能导致反渗透系统一段压差增加;(3)还有可能导致二段压差增加,一上所有设计缺陷都有可能导致系统产水量降低。
1.2.2 反渗透添加剂及其它耗材选用不当
(1)反渗透阻垢剂类型或加药量选用不当,如:反渗透阻垢剂类型与源水不相兼容,譬如源水中含有铝离子、铁离子或者预处理加药中使用了铁、铝等絮凝剂,尽量选择有机瞵系的反渗透阻垢剂,尽量避免采用聚羧酸型;反渗透阻垢剂的加药量一般在2―4ppm之间(按进水量计算),最多不能超过6ppm等,阻垢剂类型与加药量的选择不当会导致系统产水量迅速下降,系统压差明显增加;(2)反渗透保安过滤器滤芯在选择过程中要确保质量可靠,号称5微米而实际精度达不到的滤芯对反渗透膜元件的安全运行时非常不利的;(3)反渗透预处理系统中的絮凝剂及助凝剂的选择不当会造成膜元件的严重污染,而杀菌剂的选择不当则使
[摘要] 随着反渗透脱盐工艺的广泛应用,反渗透膜的污染因其与处理工艺、预处理效果以及各地水源水质的不同,会产生各种各样的污染。反渗透膜污染到一定程度,就必须进行清洗。而反渗透膜在遭受重度污染的情况下,在线清洗已经不能够满足膜元件性能恢复的需要,离线清洗就成为解决这一问题的唯一办法。本文主要介绍了反渗透膜重度污染的原因、特征以及离线清洗操作方法、清洗配方的选择和清洗实例,以供同行参阅。
[关键词] 反渗透;重度污染;离线清洗
The serious contamination and cleaning off-line of RO membrane
SONG Jing-po
(Begin chemical,zhengzhou 450012,China)
Abstract: With the application of RO unit,contamination appears in different forms due to different preconditions and different water sources. The problems of the cleaning of membrane is following with the contamination. But the cleaning on-line become not enough when the contamination is serious, the only choice is the cleaning off-line. This paper introduces the reasons and characteristics of serious contaminated RO membrane,the selection of prescription of the cleaning membrane,emphases on operation and concrete examples in order to consult with professionals.
Key words:reverse osmosis(RO);serious contamination;cleaning off-line
反渗透系统因其先进的技术及经济特性,已形成国内各行业庞大的用户群,据不完全统计,目前国内反渗透水处理用户已超过数千家。
反渗透膜元件作为深层的过滤手段,其表面不可避免的会残留有胶体、微生物、杂质颗粒及难溶盐类在其表面的析出,因此,在多种领域使用的反渗透装置,一旦投入使用,最终都需要清洗,只是清洗周期的长短不同而已。然而,在线清洗作为一种反渗透系统清洗保养、冲击性杀菌以及定期保护的手段,在面临反渗透膜元件重度污染时就显得无能为力,这个时候就需要对反渗透膜元件进行离线清洗。
1 反渗透膜元件重度污染的原因、特征
虽然反渗透系统的设计中都会有一定程度的富裕量,以保证在紧急时刻不至于因为反渗透系统的产水量或脱盐率下降、反渗透系统压差升高而使得供水不足而对安全生产造成威胁,但实际上也正是由于这些富裕量的存在才使得有时候隐藏的故障不能够及时的表现出来,这样最终可能就演变为反渗透膜元件的重度污染。
1.1 反渗透膜元件重度污染的概念
指反渗透系统进水中所含的悬浮物、胶体、有机物、微生物及其它颗粒对RO膜产生的表面附着、沉积污染或者水中的化学离子成分在膜表面因浓差极化等因素导致的离子积大于溶度积后的化学垢类生成等现象。重度污染则指污染后的单段压差大于系统投运初期单段压差值的2kgf/cm2以上、反渗透系统产水量较额定产水量下降30%以上、进水压力超过正常压力3kgf/cm2以上或者单支反渗透膜元件重量超过正常数值3公斤以上的情况。
重度污染往往是重度物理污染和重度化学污染的叠加,某些情况下,二者同时伴生。
1.2 反渗透膜元件重度污染的原因及特征
由于各地水源水质不同,所采用的与处理方式也不尽相同,所以RO膜元件的原因也不尽相同,常见的污染原因及特征有以下几种:
1.2.1 水处理工艺系统设计及制造缺陷
(1)对于反渗透预处理过滤器来讲,源水未井水的情况下,设备滤速大于8.5米/小时,而地表水设计中设备滤速大于8米/小时,导致反渗透进水SDI超标;(2)源水中含有胶体、悬浮物等杂质,而在设计中没有去除措施;(3)源水中COD>3而没有去除措施;(4)反渗透膜元件设计通量超标的反渗透装置二段结垢及压差升高快,产水量衰减及脱盐率下降快.
以上(1)、(2)、(3)设计缺陷可能导致反渗透系统一段压差增加;(3)还有可能导致二段压差增加,一上所有设计缺陷都有可能导致系统产水量降低。
1.2.2 反渗透添加剂及其它耗材选用不当
(1)反渗透阻垢剂类型或加药量选用不当,如:反渗透阻垢剂类型与源水不相兼容,譬如源水中含有铝离子、铁离子或者预处理加药中使用了铁、铝等絮凝剂,尽量选择有机瞵系的反渗透阻垢剂,尽量避免采用聚羧酸型;反渗透阻垢剂的加药量一般在2―4ppm之间(按进水量计算),最多不能超过6ppm等,阻垢剂类型与加药量的选择不当会导致系统产水量迅速下降,系统压差明显增加;(2)反渗透保安过滤器滤芯在选择过程中要确保质量可靠,号称5微米而实际精度达不到的滤芯对反渗透膜元件的安全运行时非常不利的;(3)反渗透预处理系统中的絮凝剂及助凝剂的选择不当会造成膜元件的严重污染,而杀菌剂的选择不当则使